Ear to the Ground

Interior Workplace Noise Control Methods Demystified

Sound intensity measurement for source indentification ranking

Noise-induced hearing loss remains a prevalent workplace injury in the modern industrial plant. So, managing workplace noise exposure is a critical responsibility for employers. Doing so can be complex – in terms of:

  • Accurately assessing sound levels and noise exposure in the workplace
  • Identifying and ranking the dominant noise sources to be targeted for mitigation
  • Finding practicable, effective and affordable noise control solutions

Many aspects of interior acoustics and noise control are counter-intuitive, and there is a great deal of myth and misinformation cluttering the common knowledge about noise. This post seeks to debunk some common misconceptions and provide a practical overview of workplace noise control. There is a “convenient truth” we can use to cut through a lot of the confusion about workplace noise control.  Quite simply, there are actually only three ways to reduce noise in an indoor environment. All workplace noise control measures can really be seen as examples or variations of the three basic noise control methods, which are:

  • Reduce the amount of sound that is produced by a given process, operation or activity
  • Block, or contain-and-dissipate the sound
  • Reduce excessive room reverberation 1

That’s it. Three options. But let’s take a closer look at how these three methods dovetail, and what some of the important details are in determining which measures suit various situations, and how they are implemented.

SOME IMPORTANT BASICS OF ACOUSTICS
The reason that all indoor noise control measures fall into just three broad categories arises from the basic fact of acoustics that there are just four fundamental factors that determine the sound level at a given location indoors:

  1. The sound emission levels of the sound sources in the room
  2. Any physical measures that may impede or dissipate the sound as it propagates from the sources to worker locations
  3. The distances from the sources to worker locations
  4. The amount of reverberation

Assuming that the distances generally cannot be changed between the sound sources and worker locations, the other factors 1, 2 and 4 represent the opportunities for noise control methods.

For reasons we will cover in the following sections, reducing the amount of sound that is produced by a given process or operation is the most effective noise control method, but is often also the most difficult to implement. Blocking or containing-and-dissipating the sound is the next most effective noise control method, and covers all of the most commonly used methods. Reducing room reverberation is only effective in a very limited number of cases.

REDUCING THE AMOUNT OF SOUND PRODUCED

In cases where a way can be found to reduce or eliminate the sound that is generated by a particular manufacturing processes, doing so is typically the most effective and eloquent solution, rather than struggling to block, contain, or absorb the sound after it emanates from the source.

Some manufacturing methods are inherently noisy when, in fact, there may be a quieter method of achieving the same production task. For example, it is common to use compressed air to guide components around turns in moving conveyors, to prevent jams; or to using rotating/vibrating hoppers to orient lightweight parts before they are fed into a processing unit. The intense “hiss” of compressed air2 and the tumbling of parts in a hopper can create sound levels greatly exceeding workplace noise exposure limits.

While this sound can be challenging to mitigate, there can be simple solutions by finding alternative conveying or sorting methods. Similarly, some machine surfaces such as lightweight sheet metal safety guards can act like a loudspeaker and efficiently turn the silent vibrations of a machine into high-level sound, via panel radiation.

If those lightweight solid panels can be replaced with perforated panels, they become inefficient at moving air, and thus do not convert vibratory energy into acoustic energy. But the examples described above are the rare “low hanging fruit.”

In many cases, there are no quieter alternative methods available to accomplish the production task, particularly in the cases of machining methods, or the intricate processing steps in the production of pharmaceuticals, petrochemicals, micro-components, etc.

Whereas we acoustical consultants are experts in the physics of sound, we are not and cannot be experts in the nuances of precision manufacturing processes.  So, in the few cases where it is feasible to reduce the at-source noise generation, the solution needs to be a collaborative effort between the process engineering team and the noise consultant. And, in many cases, reducing the noise generated at the source is just not practicable.

REVERBERATION CONTROL WITH  ACOUSTICAL ABSORPTION

Absorptive baffles suspended from ceilings

Reducing noise by controlling reverberation is another method that is, unfortunately, only effective in a relatively small number of cases. Nevertheless, it is important to understand the benefits and limits of using acoustically absorptive materials to reduce reverberation.

When sound is released into any enclosed space – such as a room, the interior of a machine enclosure, or the cavity inside a double-layer wall – those sound waves will continue to travel around inside the space until they are absorbed through successive reflections off of the interior surfaces. If the interior surfaces are primarily reflective, the acoustic energy will accumulate as more interior sound is released into the space, and the resulting sound levels will be greater – sometimes much greater – than if the same amount of sound were released into an unenclosed space or one with adequate acoustical absorption.

When this build-up of sound occurs in a room, it is termed “reverberation.” If the surface finishes in a room do not provide adequate acoustical absorption, the reverberation can be excessive, which can adversely elevate the sound levels within. Similarly, if there is little or no acoustical absorption inside a machine enclosure, the interior sound levels will escalate until the point at which the amount of sound transmitted out through the enclosure walls approaches the amount of sound emitted from the sources within, such that the enclosure will provide minimal sound containment.

Therefore, acoustical absorption is an important element in noise control. If an enclosure around a machine is to serve as an acoustical enclosure, it must include – among other features – some interior acoustical absorption to dissipate the contained sound; otherwise it will be ineffective.

To be effective as an acoustical absorber, a material typically must be fibrous or micro-porous, such as fiberglass batt or open-cell foam, and have a thickness that is about 1/7th or more than the wavelength of the lowest acoustical frequency that needs to be absorbed. Thin materials will only absorb high frequencies, but thicker materials (e.g., 4” or thicker) will absorb both high and low-frequency sound. These materials function by converting acoustic energy, which is the oscillation of air molecules, into heat, by viscous friction. As the air molecules vibrate in and out of the tiny, tortuous capillaries between the fibers or pores. Manufacturers of absorptive materials can optimize the performance by adjusting the fiber diameter, pore size, bulk density and thickness of the material.

In some manufacturing environments with Good Manufacturing Practice (“GMP”) restrictions, such as food processing, pharmaceutical production, or cleanrooms, the use of absorptive materials can be a challenge, because they can shed fibers, foster microbial growth, or allow cross-contamination by accumulating and re-releasing micro-particles. In these cases, the absorptive materials can be faced with a thin, impervious material such as foil, paper, or polymer.

However, doing so reduces the absorptivity of the material. There are also non-porous absorbers such as thin films or foils stretched over a backing air cavity – which function by diaphragmatic action, like a loudspeaker in reverse – or tuned resonators. But these devices are often effective only at one specific acoustic frequency, or a narrow range of frequency. The absorbers with the broadest effectiveness are bulk fibrous or porous materials. It is also important to note that not all thermal insulators are good acoustical absorbers. Closed-cell foams such as Styrofoam, expanded polystyrene and most spray foams have no open pores or fibrous capillaries to dissipate sound, so they provide virtually no acoustical benefit whatsoever.

Unfortunately, though – while acoustical absorption is important in controlling reverberation, there is often already an adequate degree of naturally occurring acoustical absorption in many rooms – such as furnishings, ceiling tiles, and occupants themselves – which may already afford appreciable absorption. In that case, there is minimal incremental benefit from any additional absorption, such as suspended acoustical baffles, fibreglass or foam wall panels, or spray-on fibrous ceiling insulation.

Moreover, it is important to understand that the total sound level impinging at a worker’s ear is composed of two parts – the direct sound and the reverberant sound. The direct portion of the sound is affected only by the loudness of the source(s), the distance between the source and the worker, and anything obstructing the travel of sound from the source to the worker. The reverberant sound is affected by the geometry of the room and the amount of acoustical absorption.

At workstations close to a sound source, the direct component of the sound is usually much greater than the reverberant component, such that a reduction of reverberant sound will have little to no effect on the total sound level.  Thus, in a majority of cases controlling reverberation will only reduce the sound levels in areas far away from the production equipment – typically locations where workers are rarely present. As a result, experience shows that the use of absorptive treatments to reduce room reverberation is rarely an acoustically effective or cost-effective solution in the workplace.

BLOCKING OR CONTAINING AND DISSIPATING THE SOUND

By a considerable margin, the noise control measures with the widest applicability in the industrial workplace environment are types of engineered noise control hardware. There are many types, but in essence they are all examples of blocking the sound, or containing and absorbing it. The following sections cover the most common, tried-and-true noise control methods.

Noise barriers that do not fully enclosure the source
Noise barriers that do not fully enclosure the source

Noise Barriers and Acoustical Enclosures
Noise barriers, usually in the form of a noise wall or other obstruction, block the sound, creating an “acoustical shadow” for a protected area. In contrast to a full acoustical enclosure, a noise barrier is typically open on top, or on one or more sides.  That is, a barrier is a partial enclosure. Although noise barriers are effective outdoors, they usually have minimal benefit indoors because of reverberation or discrete acoustical reflections (e.g., from the ceiling), and because of constraints on size.

Some amount of sound always diffracts over the top or around the open sides of the barrier. Therefore, acoustical enclosures are generally the most common and effective noise control measure in the manufacturing environment.

An acoustical enclosure functions by effectively containing the sound and then dissipating it by absorption. In order to contain the sound, the enclosure walls must be air-impervious and have sufficient mass (depending on the magnitude and frequency of the sound being contained).

Any openings in the enclosure – e.g., to allow ingress and egress of product or ventilation/cooling-air – must be fitted with silencers or acoustically lined passages. Otherwise, any joints, gaps or cracks must be sealed air-tight. Even a small unsilenced gap or opening can dramatically degrade or nullify the containment of the sound. In some cases, items of equipment targeted for noise control already have integral enclosures, for safety or product quality reasons. However, because of openings or gaps, and absence of interior acoustical absorption, they do not naturally afford appreciable acoustical benefit.

Sometimes these enclosures can be upgraded to function as effective noise control measures, by sealing gaps, providing interior absorption, and devising silenced openings for ingress/egress of product materials and cooling air.

Acoustical Pipe Lagging
Acoustical Pipe Lagging

Acoustical Lagging
For pipes and vessels, acoustical “lagging” (wrapping) is a common noise control method, as it can be less cumbersome than a full acoustical enclosure. In essence, acoustical lagging is simply a conformal acoustical enclosure that is supported on the surface of the noise source itself, rather than being self-supporting. It consists of one or more layers of fibrous or porous material, potentially one or more intermediate limp, air-impervious barrier layers, and a heavy air-impervious outer jacket.

The most common jacket material consists of a protective aluminum or stainless steel cladding, with limp mass-loaded vinyl laminated to the backside, facing the insulation, and is available from noise control suppliers. For complex shaped equipment, there are mastic products available for the outer jacket, which can be trowel applied over the insulation layer, and which then cure in place. The fibrous or porous layers provide acoustical absorption, but also act as a resilient support for the outer sound-containing jacket, in order to partially decouple it from the vibrating surface of the pipe or vessel.

It is important to note that, the maximum noise reduction possible from acoustical lagging is less than that of a fully decoupled acoustical enclosure, because of the contact, albeit resilient, between the surface of the noise source and the outer jacket.  As well, while acoustical lagging is effective for high-frequency noise, in the 500 to 5000 Hz range, it tends to amplify sound at low frequencies, and is therefore unsuitable for sources that produce appreciable low-frequency noise.

Acoustical enclosure with louvered door and reactive muffler discharge
Acoustical enclosure with louvered door and reactive muffler discharge

Silencers and Acoustical Louvers
A silencer is a common and effective noise control measure which allows flow-through of air or other gases but which removes some portion of the acoustic energy from the gas flow that passes through it. Silencers can be fitted on the intake or outlet of a fan, or in a ventilation opening in an enclosure.

A “dissipative” (i.e., absorptive) silencer is an acoustically lined passage (or a bundle of acoustically lined passages arranged in parallel).  An acoustical louver is simply a short acoustical silencer with a depth suitable for installing flush in a wall. The acoustical lining is typically fibrous or porous insulation material, but for GMP areas the insulation can be wrapped with an impervious facing.

Absorptive silencers, round and rectangular
Absorptive silencers,
round and rectangular

In some cases, no-media (“packless”) silencers can be used. Reactive silencers, sometimes called mufflers, consisting of an interconnecting series of tuned internal cavities and tubes, etc., which use resonance and anti-resonance to attenuate the sound passing downstream.  Nozzle silencers, which are small devices typically threaded into a compressed-air release port, use porous elements and aerodynamic geometries to smooth the flow and eliminate turbulent shear noise.

All of these types of silencers will constrict the airflow to some degree, resulting in additional back-pressure to the flow path. Typically, the additional backpressure is proportional to increasing acoustical attenuation, so the acoustical performance must be balanced against the allowable incremental backpressure that the system can accommodate. The additional backpressure can generally be minimized by using silencers with greater cross-sectional dimensions and/or length, if the available space allows.

Active Noise Control
In a small number of special cases, “active noise control” may be effective.  Active noise control, or “noise cancellation” describes the method of using destructive wave interference to neutralize the sound produced by a source.

In principle, one or more microphones are used to capture the sound emitted by the source, and that signal is fed to a digital processor which creates an inverse (mirror image) signal that is injected back into the sound field through one or more loudspeakers.  Perfect cancellation is not possible, but in some cases, appreciable reductions in noise can be achieved.

In general, though, this method is only successful for sound within a small confined space, such as a duct, inside an ear-muff, or a vehicle cabin. As well, in practice, active noise control is primarily only successful when the sound is a low frequency “pure tone” (composed primarily of one frequency, less than about 500 Hz).  Moreover, there are currently no off-the-shelf active noise control products – a custom system must be developed, designed, tested, refined, and installed for each different application.

CONCLUDING SUMMARY
The best noise control solution always depends on the specifics of the noisy equipment, the setting in which it is located, and the way that workers need to interact with the production processes. In most situations, a combination of the methods discussed above is necessary.  The key to resolving an existing noise issue – or preventing one at the design stage – is to identify the dominant noise sources and transmission paths, rank them in terms of significance in contributing to the overall sound levels in the work environment, and select the best combination of engineered noise control solutions based on an understanding of the fundamentals of acoustics, outlined above.

An edited version of this article originally appeared in the November December 2019 issue of Occupational Health & Safety Magazine.

1. Reverberation is the tendency of sound to linger, and it occurs as a result of the sound bouncing around inside an enclosed space, reflecting and re-reflecting off of the many room surfaces. The amount of reverberation depends on how acoustically absorptive or reflective the interior surfaces of the room are. Excessive reverberation in a room increases the amount of noise by allowing the sound to build up in a cumulative fashion – in effect amplifying the sound that is being emitted by the sources.

2. When compressed air is used to move or guide components, it can generate high intensity, high-frequency noise both when it exits a nozzle at high pressure, and as it hits the component being moved/guided. The former can sometimes be reduced somewhat using aerodynamically optimized “silencer” nozzles, but the latter is difficult or impossible to ameliorate, because the noise is produced when the air impinges on the component, and “shears” across its edges.